| URI | 
          http://vocab.nerc.ac.uk/collection/P02/current/CMFL/ | 
        
        
          | Within Vocab | 
          SeaDataNet Parameter Discovery Vocabulary | 
        
        
        
          | Alternative Labels | 
          
            
              Var_fluor
            
           | 
        
        
        
          | Definition | 
          Parameters measured by variable fluorescence instruments such as pump and probe and fast repetition rate fluorometers | 
        
        
          | Date | 
          2005-02-03T11:20:5 | 
        
        
        
          
            
              | Identifier | 
              SDN:P02::CMFL | 
            
          
            
              | Note | 
              accepted | 
            
          
        
        
          
            
              | Has Current Version | 
              2 | 
            
          
        
        
        
          | Version | 
          
            
              1
              
          
           | 
        
        
        
        
          
            
              | version | 
              2 | 
            
          
            
              | inScheme | 
              http://vocab.nerc.ac.uk/scheme/EDMED_DCAT_THEMES/current/ | 
            
          
        
        
        
        
            
            | 
              Same As
             | 
			
				
					
					
                OD1:FLUO | 
                Fluorescence | 
            Mapping: 1855150 | 
					
				
				
					
				
			
        
            
            | 
              Broader
             | 
			
				
					
					
                P22:28 | 
                Oceanographic geographical features | 
            Mapping: 172525 | 
					
				
				
					
						
				
			
				
					
						
						| 
					
					
                 | D01:D0100001 | 
                Parameters | 
            Mapping: 1392503 | 
					
				
				
					
						
				
			
				
					
						
						| 
					
					
                 | P03:O010 | 
                Rate measurements (including production, excretion and grazing) | 
            Mapping: 1860 | 
					
				
				
					
						
				
			
				
					
						
						| 
					
					
                 | L19:005 | 
                theme | 
            Mapping: 206400 | 
					
				
				
					
						
				
			
				
					
					
						
							| 
                 | P05:002 | 
                biota | 
            Mapping: 33094 | 
						
					
						
							| 
                 | P05:014 | 
                oceans | 
            Mapping: 33131 | 
						
					
				
				
					
						
				
			
        
            
            | 
              Narrower
             | 
			
				
					
					
						
							| 
                 | P01:COFLPP01 | 
                Constant in-vivo fluorescence (chlorophyll) of the water body by in-situ pump and probe chlorophyll fluorometer | 
            Mapping: 378234 | 
						
					
						
							| 
                 | P01:NS01FR02 | 
                Functional absorption cross-section standard deviation {Sigma-PSII} in the water body by single turnover fast repetition rate (FRR) fluorometry | 
            Mapping: 871740 | 
						
					
						
							| 
                 | P01:SIGPSII1 | 
                Functional absorption cross-section {Sigma-PSII} in the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber | 
            Mapping: 387714 | 
						
					
						
							| 
                 | P01:SIGFRBL2 | 
                Functional absorption cross-section {Sigma-PSII} in the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the dark chamber | 
            Mapping: 446002 | 
						
					
						
							| 
                 | P01:SIGFRBL1 | 
                Functional absorption cross-section {Sigma-PSII} in the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the light chamber | 
            Mapping: 445998 | 
						
					
						
							| 
                 | P01:SIGMFR01 | 
                Functional absorption cross-section {Sigma-PSII} in the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber | 
            Mapping: 427270 | 
						
					
						
							| 
                 | P01:SIGMFR02 | 
                Functional absorption cross-section {Sigma-PSII} in the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the raw data from the light chamber | 
            Mapping: 427442 | 
						
					
						
							| 
                 | P01:NS01FR01 | 
                Functional absorption cross-section {Sigma-PSII} in the water body by single turnover fast repetition rate (FRR) fluorometry | 
            Mapping: 871736 | 
						
					
						
							| 
                 | P01:CMFLPP01 | 
                Maximum in-vivo fluorescence (chlorophyll) of the water body by in-situ pump and probe chlorophyll fluorometer | 
            Mapping: 378238 | 
						
					
						
							| 
                 | P01:FMMAXIBL | 
                Maximum in-vivo fluorescence (chlorophyll) {Fm} of the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the dark chamber | 
            Mapping: 388114 | 
						
					
						
							| 
                 | P01:FMMAXI01 | 
                Maximum in-vivo fluorescence (chlorophyll) {Fm} of the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber | 
            Mapping: 387702 | 
						
					
						
							| 
                 | P01:FMFIRB01 | 
                Maximum in-vivo fluorescence (chlorophyll) {Fm} of the water body by fluorescence induction and relaxation (FIRe) fluorometer and derivation from the blank-corrected raw data from the dark chamber | 
            Mapping: 446006 | 
						
					
						
							| 
                 | P01:FMMAXD01 | 
                Maximum in-vivo fluorescence (chlorophyll) {Fm} of the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the dark chamber | 
            Mapping: 446014 | 
						
					
						
							| 
                 | P01:FMMAXL01 | 
                Maximum in-vivo fluorescence (chlorophyll) {Fm} of the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the light chamber | 
            Mapping: 446010 | 
						
					
						
							| 
                 | P01:CMFLFR01 | 
                Maximum in-vivo fluorescence (chlorophyll) {Fm} of the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber | 
            Mapping: 427246 | 
						
					
						
							| 
                 | P01:CMFLFR02 | 
                Maximum in-vivo fluorescence (chlorophyll) {Fm} of the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the raw data from the light chamber | 
            Mapping: 427250 | 
						
					
						
							| 
                 | P01:FOMINIBL | 
                Minimum in-vivo fluorescence (chlorophyll) {Fo} of the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the dark chamber | 
            Mapping: 388338 | 
						
					
						
							| 
                 | P01:FOMINI01 | 
                Minimum in-vivo fluorescence (chlorophyll) {Fo} of the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber | 
            Mapping: 387706 | 
						
					
						
							| 
                 | P01:FOFIRB01 | 
                Minimum in-vivo fluorescence (chlorophyll) {Fo} of the water body by fluorescence induction and relaxation (FIRe) fluorometer and derivation from the blank-corrected raw data from the dark chamber | 
            Mapping: 446018 | 
						
					
						
							| 
                 | P01:FOMIND01 | 
                Minimum in-vivo fluorescence (chlorophyll) {Fo} of the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the dark chamber | 
            Mapping: 446026 | 
						
					
						
							| 
                 | P01:FOMINL01 | 
                Minimum in-vivo fluorescence (chlorophyll) {Fo} of the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the blank-corrected raw data from the light chamber | 
            Mapping: 446022 | 
						
					
						
							| 
                 | P01:COFLFR01 | 
                Minimum in-vivo fluorescence (chlorophyll) {Fo} of the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber | 
            Mapping: 427254 | 
						
					
						
							| 
                 | P01:COFLFR02 | 
                Minimum in-vivo fluorescence (chlorophyll) {Fo} of the water body by in-situ fast repetition rate fluorometer (FRRF) and derivation from the raw data from the light chamber | 
            Mapping: 427258 | 
						
					
						
							| 
                 | P01:NF01FR02 | 
                Photochemical quantum efficiency standard deviation {Fv/Fm} in the water body by single turnover fast repetition rate (FRR) fluorometry | 
            Mapping: 871732 | 
						
					
						
							| 
                 | P01:FVFMFR01 | 
                Photochemical quantum efficiency {Fv/Fm or Phi} in the water body by in-situ fast repetition rate fluorometer (FRRF) and calculation from Fm and Fo fluorescence yields from the dark chamber | 
            Mapping: 427262 | 
						
					
						
							| 
                 | P01:FVFMFR02 | 
                Photochemical quantum efficiency {Fv/Fm or Phi} in the water body by in-situ fast repetition rate fluorometer (FRRF) and calculation from Fm and Fo fluorescence yields from the light chamber | 
            Mapping: 427266 | 
						
					
						
							| 
                 | P01:FVFMMIBL | 
                Photochemical quantum efficiency {Fv/Fm} in the water body by bench fast repetition rate fluorometer (FRRF) and calculation from blank-corrected Fm and Fo fluorescence yields from the dark chamber | 
            Mapping: 388786 | 
						
					
						
							| 
                 | P01:FVFMMI01 | 
                Photochemical quantum efficiency {Fv/Fm} in the water body by bench fast repetition rate fluorometer (FRRF) and calculation from Fm and Fo fluorescence yields from the dark chamber | 
            Mapping: 387710 | 
						
					
						
							| 
                 | P01:FVFMFIRX | 
                Photochemical quantum efficiency {Fv/Fm} in the water body by fluorescence induction and relaxation (FIRe) fluorometer and calculation from blank-corrected Fm and Fo fluorescence yields from the dark chamber | 
            Mapping: 446034 | 
						
					
						
							| 
                 | P01:FVFMFIR1 | 
                Photochemical quantum efficiency {Fv/Fm} in the water body by fluorescence induction and relaxation (FIRe) fluorometer and calculation from Fm and Fo fluorescence yields from the dark chamber | 
            Mapping: 446030 | 
						
					
						
							| 
                 | P01:FVFMFR04 | 
                Photochemical quantum efficiency {Fv/Fm} in the water body by in-situ fast repetition rate fluorometer (FRRF) and calculation from blank-corrected Fm and Fo fluorescence yields from the dark chamber | 
            Mapping: 446042 | 
						
					
						
							| 
                 | P01:FVFMFR03 | 
                Photochemical quantum efficiency {Fv/Fm} in the water body by in-situ fast repetition rate fluorometer (FRRF) and calculation from blank-corrected Fm and Fo fluorescence yields from the light chamber | 
            Mapping: 446038 | 
						
					
						
							| 
                 | P01:NF01FR01 | 
                Photochemical quantum efficiency {Fv/Fm} in the water body by single turnover fast repetition rate (FRR) fluorometry | 
            Mapping: 871728 | 
						
					
						
							| 
                 | P01:NT01FR02 | 
                Rate of Qa reoxidation standard deviation {1/TauQa} in the water body by single turnover fast repetition rate (FRR) fluorometry | 
            Mapping: 871724 | 
						
					
						
							| 
                 | P01:TAUQAI01 | 
                Rate of Qa reoxidation {1/TauQa} in the water body by bench fast repetition rate fluorometer (FRRF) and derivation from the raw data from the dark chamber | 
            Mapping: 387902 | 
						
					
						
							| 
                 | P01:NT01FR01 | 
                Rate of Qa reoxidation {1/TauQa} in the water body by single turnover fast repetition rate (FRR) fluorometry | 
            Mapping: 871720 | 
						
					
				
				
					
				
			
        
            
            | 
              Related
             | 
			
				
					
					
                P04:G945 | 
                EARTH SCIENCE > Oceans > Ocean Optics > Fluorescence | 
            Mapping: 850 | 
					
				
				
					
						
				
			
				
					
						
						| 
					
					
                 | P64:G945 | 
                EARTH SCIENCE > Oceans > Ocean Optics > Fluorescence | 
            Mapping: 502218 | 
					
				
				
					
						
				
			
				
					
						
						| 
					
					
                 | P03:B035 | 
                Pigments | 
            Mapping: 1971 |