Concept
CONFIG_CTDPumpStopPressure_dbar
URI | http://vocab.nerc.ac.uk/collection/R18/current/CC00030/ | |
---|---|---|
Within Vocab | Argo configuration parameter names | |
Alternative Labels | Core Config 30 - Optional | |
Definition | The pressure at which the CTD pump is switched off. As the float ascends, the code looks at the pressure and if <= CONFIG_CTDPumpStopPressure, the CTD is turned off. CTDPumpStopPressure is a firmware threshold and as such, data may continue to be collected for a limited span after the threshold is recognized. Especially in floats that return high resolution discrete data, there might be data collected shallower than the cut off, due to the discrete nature of the pressure data and also due to the time necessary for the firmware to turn off the CTD once the pressure threshold is reached. For example for SOLOII floats the CTD is switched off at 1dbar, and typically the shallowest data is from 0.5 to 0.8 dbar. This shallow data should be carefully assessed for its validity. | |
Date | 2023-05-02T16:34:05 | |
Identifier | SDN:R18::CC00030 | |
Note | accepted | |
Has Current Version | 1 | |
version | 1 |
Alternate Formats
Other formats for this page:
RDF/XML Turtle JSON-LDAlternate Profiles
Other views of this page:
Alternate Profiles ?Different Media Types (HTML, text, RDF, JSON etc.) and different information model views, profiles, are available for this resource.
NVS html view ? Default NVS html view.