Concept
CONFIG_IceDetectionConnectionTimeOut_minutes
| URI | http://vocab.nerc.ac.uk/collection/R18/current/CC00072/ | |
|---|---|---|
| Within Vocab | Argo configuration parameter names | |
| Alternative Labels | Core Config 72 | |
| Definition | Time out. This is similar to CONFIG_ConnectionTimeOut_minutes but for the first telemetry session of a float in ice detection mode. In ice detection mode, the float reduces the timeout of the first Iridium connection: if the first connection fails the cycle is aborted (ice probably present) but if the first connection succeeds (waters free of ice) the float switches to the nominal timeout (CONFIG_ConnectionTimeOut_minutes) for the following transmissions of the current cycle. Template_Values:{unit:[days, hours, minutes, seconds]}. | |
| Date | 2025-12-12T11:41:04 | |
| Identifier | SDN:R18::CC00072 | |
| Note | accepted | |
| Has Current Version | 2 | |
| Version | 1 | |
| version | 2 | |
Alternate Formats
Other formats for this page:
RDF/XML Turtle JSON-LDAlternate Profiles
Other views of this page:
Alternate Profiles ?Different Media Types (HTML, text, RDF, JSON etc.) and different information model views, profiles, are available for this resource.
NVS html view ? Default NVS html view.