| URI | 
          http://vocab.nerc.ac.uk/collection/S04/current/S041073/ | 
        
        
          | Within Vocab | 
          BODC parameter semantic model analytical method entity descriptions | 
        
        
        
          | Alternative Labels | 
          
            
              TIMS
            
           | 
        
        
        
          | Definition | 
          A highly sensitive isotope mass spectrometry characterization technique in which a chemically purified sample is heated to cause ionization of the atoms of the sample. The resulting ions are focused into a beam by an electromagnet, then separated into individual beams based on the mass/charge ratio of the ions. | 
        
        
          | Date | 
          2012-08-17T15:54:24 | 
        
        
        
          
            
              | Identifier | 
              SDN:S04::S041073 | 
            
          
            
              | Note | 
              accepted | 
            
          
        
        
          
            
              | Has Current Version | 
              1 | 
            
          
        
        
        
        
          
            
              | version | 
              1 | 
            
          
        
        
        
        
            
            | 
              Broader
             | 
			
				
					
					
                S01:S0110 | 
                analytical method entity | 
            Mapping: 1472503 | 
					
				
				
					
				
			
        
            
            | 
              Related
             | 
			
				
					
					
						
							| 
                 | P01:NDKG06MS | 
                Concentration combined uncertainty of neodymium {Nd CAS 7440-00-8} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and thermal ionization mass spectrometry | 
            Mapping: 810160 | 
						
					
						
							| 
                 | P01:CDKGTIMS | 
                Concentration of cadmium {Cd CAS 7440-43-9} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 834530 | 
						
					
						
							| 
                 | P01:NDKG05MS | 
                Concentration of neodymium {Nd CAS 7440-00-8} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and thermal ionization mass spectrometry | 
            Mapping: 810148 | 
						
					
						
							| 
                 | P01:NDKG05MT | 
                Concentration of neodymium {Nd CAS 7440-00-8} per unit mass of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, acidification and thermal ionization mass spectrometry | 
            Mapping: 886422 | 
						
					
						
							| 
                 | P01:ND02TIMS | 
                Concentration of neodymium {Nd CAS 7440-00-8} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 802690 | 
						
					
						
							| 
                 | P01:CNE87003 | 
                Concentration of neodymium {Nd CAS 7440-00-8} per unit volume of the water body [particulate >0.8um phase] by filtration, acid digestion and thermal ionization mass spectrometry | 
            Mapping: 885462 | 
						
					
						
							| 
                 | P01:NDSE02MS | 
                Concentration standard error of neodymium {Nd CAS 7440-00-8} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 802868 | 
						
					
						
							| 
                 | P01:CD112SRM | 
                Enrichment with respect to 112Cd/110Cd in NIST SRM 3108 of cadmium-112 {112Cd CAS 14336-65-3} {epsilon(112/110)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 1475000 | 
						
					
						
							| 
                 | P01:CD112SEM | 
                Enrichment with respect to 112Cd/110Cd in NIST SRM 3108 standard error of cadmium-112 {112Cd CAS 14336-65-3} {epsilon(112/110)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 1474986 | 
						
					
						
							| 
                 | P01:DTEFFICP | 
                Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 of cadmium-114 {114Cd CAS 14041-58-8} {delta(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry and using the delta notation | 
            Mapping: 1530428 | 
						
					
						
							| 
                 | P01:CDEFFICP | 
                Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 of cadmium-114 {114Cd CAS 14041-58-8} {epsilon(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 879744 | 
						
					
						
							| 
                 | P01:DTA87001 | 
                Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 standard error of cadmium-114 {114Cd CAS 14041-58-8} {delta(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry and using the delta notation | 
            Mapping: 1530510 | 
						
					
						
							| 
                 | P01:ECA87001 | 
                Enrichment with respect to 114Cd/110Cd in NIST SRM 3108 standard error of cadmium-114 {114Cd CAS 14041-58-8} {epsilon(114)Cd} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 885330 | 
						
					
						
							| 
                 | P01:NDCHUR05 | 
                Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) combined uncertainty of neodymium-143 {143Nd CAS 14336-83-5} {epsilon Nd value propagated error} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 810186 | 
						
					
						
							| 
                 | P01:NDCHUR04 | 
                Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) of neodymium-143 {143Nd CAS 14336-83-5} {epsilon Nd value} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 810174 | 
						
					
						
							| 
                 | P01:ND143CHU | 
                Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) of neodymium-143 {143Nd CAS 14336-83-5} {epsilon(143)Nd} in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 810098 | 
						
					
						
							| 
                 | P01:NDCHUR1Z | 
                Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) of neodymium-143 {143Nd CAS 14336-83-5} {epsilon(143)Nd} in the water body [dissolved plus reactive particulate phase] by thermal ionization mass spectrometry | 
            Mapping: 810072 | 
						
					
						
							| 
                 | P01:ENE87001 | 
                Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) of neodymium-143 {143Nd CAS 14336-83-5} {epsilon(143)Nd} in the water body [particulate >0.8um phase] by filtration, acid digestion and thermal ionization mass spectrometry | 
            Mapping: 885436 | 
						
					
						
							| 
                 | P01:ND143SEC | 
                Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) standard error of neodymium-143 {143Nd CAS 14336-83-5} {epsilon(143)Nd} in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and thermal ionization mass spectrometry | 
            Mapping: 810084 | 
						
					
						
							| 
                 | P01:NDSECH1Z | 
                Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) standard error of neodymium-143 {143Nd CAS 14336-83-5} {epsilon(143)Nd} in the water body [dissolved plus reactive particulate phase] by thermal ionization mass spectrometry | 
            Mapping: 810060 | 
						
					
						
							| 
                 | P01:ENE87002 | 
                Enrichment with respect to 143Nd/144Nd in the CHondritic Uniform Reservoir (CHUR) uncertainty of neodymium-143 {143Nd CAS 14336-83-5} {epsilon(143)Nd} in the water body [particulate >0.8um phase] by filtration, acid digestion and thermal ionization mass spectrometry | 
            Mapping: 885448 |