URI |
http://vocab.nerc.ac.uk/collection/S06/current/S0600277/ |
Within Vocab |
BODC parameter semantic model parameter entity names |
Alternative Labels |
|
Definition |
A measure of acidity based on the free proton (hydrogen ion) concentration plus hydrogen sulfate ion concentration. |
Date |
2021-11-01T11:53: |
Identifier |
SDN:S06::S0600277 |
Note |
accepted |
Has Current Version |
2 |
Version |
1
|
version |
2 |
Narrower
|
| P01:PHMASSSD |
pH (total scale) standard deviation of the water body |
Mapping: 1706254 |
| P01:PHSDECAL |
pH (total scale) standard deviation {pH[T]} of the experiment water sample by computation |
Mapping: 1706198 |
| P01:PHTLSDWC |
pH (total scale) standard deviation {pH[T]} of the water body by computation |
Mapping: 1706146 |
| P01:PHTLECAL |
pH (total scale) {pH[T]} of the experiment water sample by computation |
Mapping: 1706174 |
| P01:PHTLMP02 |
pH (total scale) {pH[T]} of the sediment pore water by model prediction |
Mapping: 1717986 |
| P01:PHMASSXX |
pH (total scale) {pH[T]} of the water body |
Mapping: 1706090 |
| P01:PHTLWCAL |
pH (total scale) {pH[T]} of the water body by computation |
Mapping: 1706104 |
| P01:PHTSFE03 |
pH (total scale) {pH[T]} of the water body by ion sensitive field-effect transistor (ISFET) sensor (external counter electrode) and manufacturer's calibration and correction against independent temperature and salinity measurements |
Mapping: 1849170 |
| P01:PHXXFE03 |
pH (total scale) {pH[T]} of the water body by ion sensitive field-effect transistor (ISFET) sensor (external counter electrode) and manufacturer's calibration applied |
Mapping: 1792925 |
| P01:PHTSFE02 |
pH (total scale) {pH[T]} of the water body by ion sensitive field-effect transistor (ISFET) sensor (internal counter electrode) and manufacturer's calibration and correction against independent temperature and salinity measurements |
Mapping: 1849160 |
| P01:PHXXFE02 |
pH (total scale) {pH[T]} of the water body by ion sensitive field-effect transistor (ISFET) sensor (internal counter electrode) and manufacturer's calibration applied |
Mapping: 1792911 |
| P01:PHTLMP01 |
pH (total scale) {pH[T]} of the water body by model prediction |
Mapping: 1710470 |
| P01:PHXXSP02 |
pH (total scale) {pH[T]} of the water body by spectrophotometry |
Mapping: 1705674 |
| P01:PHXXSP05 |
pH (total scale) {pH[T]} of the water body by spectrophotometry (external electrode) and manufacturer's calibration and correction against independent temperature and salinity measurements |
Mapping: 1706392 |
| P01:PHXXSP07 |
pH (total scale) {pH[T]} of the water body by spectrophotometry (external electrode) and manufacturer's calibration and laboratory calibration against TRIS-buffer applied |
Mapping: 1706412 |
| P01:PHXXSP04 |
pH (total scale) {pH[T]} of the water body by spectrophotometry (external electrode) and manufacturer's calibration applied |
Mapping: 1706382 |
| P01:PHXXSP06 |
pH (total scale) {pH[T]} of the water body by spectrophotometry (internal electrode) and manufacturer's calibration and correction against independent temperature and salinity measurements |
Mapping: 1706402 |
| P01:PHXXSP03 |
pH (total scale) {pH[T]} of the water body by spectrophotometry (internal electrode) and manufacturer's calibration applied |
Mapping: 1706372 |